
Vortice AXIAL K Aspirator - 64 db - air flow rate 135 m3 / h - white

The Vortice Axial K vacuum cleaner is made of aging-resistant plastic resin due to exposure to the sun ("UV resistant"), 1 speed thermally protected motor, with shaft mounted on self-lubricating bronze supports with coupled centrifugal impeller
Satisfied or refunded: up to 14 days from the delivery date to return your purchase
Visa - MasterCard - PayPal - Scalapay - Bank transfer
Product features
Centrifugal extractor fans for hood
Description
• Construction in plastic resin resistant to aging due to exposure to the sun ("UV resistant").
• Nominal diameter: 100 mm
• Thermally protected 1-speed motor, with shaft mounted on self-lubricating bronze bearings with coupled centrifugal impeller
• Maximum flow rate 135 m3 / h
• Protective grille on the suction mouth
• IMQ and IMQ PERFORMANCE certified safety and performance
• Speed controllable by Vortex regulator.
Data sheet
Technical and performance data
Max absorbed current (A) 0.13
Nominal Conduit Diameter (mm) 100
Frequency (Hz) 50
Degree of protection IP X2
2nd class insulation
Weight (Kg) 1,2
Max absorbed power (W) 27
Max ambient temperature for continuous operation (° C) 40
Voltage (V) 220-240
Max flow rate (l / s) 37.5
Max flow rate (m³ / h) 135
Max pressure (mmH2O) 17
Max pressure (Pa) 167
Sound pressure level Lp [dB (A)] 3m41
RPM 2560
Energy data
Name or trade name of the manufacturer Vortice
Specific energy consumption class for temperate climate NA
Specific energy consumption SEC (temperate climate) [kWh / m2a] -1.8
Specific energy consumption SEC (cold climate) [kWh / m2a] -10.5
Specific energy consumption SEC (hot climate) [kWh / m2a] 10.5
Declared type of UVR-U ventilation unit: unidirectional
Drive type NA
Type HRS heat exchanger absent
Thermal efficiency of heat recovery at the reference flow rate HRS [%] NA
Maximum flow rate [m3 / h] 78
Total electric power absorbed by the fan at maximum capacity [W] 27.0
Sound power level LWA [dB (A)] 64
Reference flow rate [m3 / s] 0.0152
Reference pressure difference [Pa] 129
SPI [W / (m3 / h)] 0.48901
Control factor CTRL 1
Type of manual control
Maximum percentage of internal leakage [%] NA
Maximum percentage of external leakage [%] NA
Mix rate NA
Location and description of visual signal for NA filters
Air flow sensitivity to pressure variations at ± 20 Pa NA
Indoor / outdoor air tightness [m3 / h] NA
AEC Annual electricity consumption [kWh electricity / a] 613
AHS tempered Annual heating savings [kWh primary energy / a] 1715
Cold AHS Annual heating savings [kWh primary energy / a] 2732
Hot AHS Annual heating savings [kWh primary energy / a] 632
Why choose us?
√ We listen to your requests and needs
√ We inform you by helping you in your choice
√ We always follow up with you, even after your purchase
Each package is photographed before being entrusted to the courier and the photo sent to your email address together with the service information. We carefully select the carrier to entrust the delivery to, based on the characteristics of the single order.


All products always leave from our headquarters, where they are scrupulously checked and reinforced in the packaging.
Each package is photographed before being entrusted to the courier and the photo sent to your email address together with the service information. We carefully select the carrier to entrust the delivery to, based on the characteristics of the single order.